Some Important Notes:

Going Forward all Hartzell propellers sold and overhauled by Canadian Propeller will be lubricated with GN3058

Repairs on Hartzell Propellers that require re-lubrication will be done with GN3058

Current in service Hartzell props must continue to be lubricated with Aeroshell 5/6 until next overhaul or disassembly by Propeller shop

Aeroshell and Nyco grease cannot be combined.

If accidentally mixed:

  • Propeller requires disassembly and cleaning which can only be performed by an approved propeller shop.  
  • Cleaning must be complied within the following: 
  • 3 months or 30 flights whichever comes first

Some Important Notes:

  • Going Forward all Hartzell propellers sold and overhauled by Canadian Propeller will be lubricated with GN3058
  • Repairs on Hartzell Propellers that require re-lubrication will be done with GN3058

To prevent any mixups with multiple greases:

  • Propellers greased with GN3058 will have a yellow warning label on either the cylinder or piston depending on application per SL-61-366 
  • The logbook will have a yellow label on the front indicating lubrication with GN3058.  
  • Compliance with HC-SL-61-366 will be indicated on the Form One within the logbook 
  • We have included yellow warning labels for your grease guns

If you have any questions, give us a call!

Toll Free 1-800-773-6853  

CONTACT US

462 Brooklyn Street, Winnipeg, Manitoba R3J 1M7

Phone: 204-832-8679
Toll-Free & AOG Line: 1-800-773-6853
Fax: 204-888-4696
Cell: 204-955-0826
Email: info@canadianpropeller.com
Web: canadianpropeller.com

For Employment Opportunities, email your resume to: projects@canadianpropeller.com

ENQUIRIES & SUPPORT

** After Hours 24/7 & AOG **

1-800-773-6853

(Or call cell phones directly)

D I R E C T  C O N T A C T S